모델명 : ETCR1000C
원산지 : CHINA
브랜드 : ETCR
Safe and Time Saving |
Traditional phase sequence measurement methods must poke the three-phase wire terminal, and connect the three bare alligator clips or test pins of phase sequence meters to the three bare firing lines, while ETCR1000C uses clamp non-contact measurement, without taking off the wire and no need to contact high-voltage bare fire-wire, the test can be made by directly clamping the three-phase insulating sheath by three super-sensitive high-insulated clamps. Conducting measurement on sheathed cable significantly improves the safety of field testing, effectively protect the operator’s personal safety and increase productivity! |
Convenient Operation |
Instrument base plate is provided with magnet, instrument can adsorbed on the metal shell when testing, the operation more convenient. |
Multi-Purpose |
In addition to phase sequence detection, it also has the functions of live wire examination, simple power detection, fire-wire identification, phase deficiency determination, break location detection, DC line break and line maintenance, equivalent to 3 induction electric pens. |
Dynamic Display |
LED dynamic display, intuitive and clear |
Sensitive and reliable |
More sensitive ETCR1000C clamp, can even sense the AC voltage signal as low as a few Volts, with a wider range of live electricity. |
Beautiful and scientific |
The three clamps of ETCR1000C are in three colors, Red, Yellow and Green; It is more in line with the distinction of three-phase line, and more scientific and artistic overall appearance. |
Ultra-low Power Consumption |
ETCR1000C has a better power-saving performance with the maximum rated power of 100mVA. |
Functions |
Phase detection (normal phase, reverse phase and phase deficiency), Live wire examination, Simple Power detection, Breakpoint location and Line maintenance. |
Power Supply |
DC3V AA Mn batteries (R6P) ×2 PCS, Continuously working for 200 hours |
AC Voltage Range(V) |
AC0~600V, 40~70Hz (Sine Wave Continuous Input) |
Clamp Wire Size |
Diameter ø1.6-ø16mm |
LED Display |
【Positive Phase Sequence】
The four phase-sequence lamps blink in order (clockwise).
【Negative Phase Sequence】
The four phase-sequence lamps blink in order (counterclockwise).
【Line-voltage Indication】L1、L2、L3 lamp light up.
【Default Phase】L1/L2/L3 lamp is off.
【Open Circuit】L1/L2/L3 lamp is off. |
Power On Indication |
Power on indication light turns on |
Auto Power off |
After 5 minutes, the meter automatically cut off power supply. |
Meter Dimension |
Width, height, thickness 70mm*75mm*30mm |
Clamp Lead Length |
0.5m |
Meter Weight |
180g (with battery) |
Working Temperature and Humidity |
-10℃~55℃; below 80%rh |
Storage Temperature and Humidity |
-20℃~60℃; below 90%rh |
Maximum Measured Voltage |
AC600V |
Dielectric Strength |
5.4kVrms |
Maximum rated Power |
100mVA |
Safety Provisions |
EN61010-1: 2001, EN61010-031: 2002, Pollution level 2, CAT Ⅲ(600V), Transient over-voltage 6000V |
Accessories |
Meter: 1 Piece; Carrying case; 1 Piece. |
-.Function;phase detection(Normal,reverse),live wire examination,simple power inspection,phase deficiency judgement,breakpoints finding and line maintenance,instrument base plate is provided with a magnet,the operation more convient. -.Display ;LED -.Power supply; DC3V AA Mn batteries(R6P) x2 PCS -.Buzzer;yes -.Line voltage range;AC 60~600V/1000V,40~70Hz(sine wave continuous input) -.Clamp wire size;pie 1.6~16mm -.Auto power off ;3minutes after booting up ,the meter automatically cut off power supply -.Dimension;70(L)x75(W)x30(H)mm -.Clamp lead length;0.5m -.Weight;180gr(with the batteries) -.Working temperature & humidity;-10~55C,below 80%RH -.Maximum measured voltage;AC600V/AC1000V -.Dielectric strength;5.4kVrms -.Maximum rated power;100mVA -.Accessories;carrting case x1pc,manual x1pc, |